Wednesday, 25 April 2018

How to setup preset speeds on an Telemecanique Altivar 11


Telemecanique Altivar 11

There are two ways of setting and depends on the application, the one most commonly used is as follows:

You set you lowest speed into LSP and then assign the inputs you are using to give you your preset speeds (LI3 and LI4). LI1 is run forward and LI2 is run reverse, so when LI1 is high (+24v) the motor will run forward at the speed set in LSP, the same will happen when LI2 is high except the motor will run reverse. With the run signal on either LI1 or LI2 and LI3 high the motor will run FWD/REV at the second speed (SP2), if LI1 or LI2 and LI4 are high the motor will run at the third speed (SP3). The fourth speed (SP4) is attained by making LI1 or LI2 high and both LI3 and LI4 high as well. So here is the way to set this up (the figures used are just for examples, you will need to set your own)

Firstly set LSP to 10Hz and HSP to 50Hz (or motor maximum frequency)
then scroll down till you see FUN and then press enter
from here press the down arrow until rrS and press enter
set rrS to LI2 this has enabled reverse onto LI2
scroll down to PS2 and press enter
set LIA to LI3
then LIB to LI4
next set SP2 to 30Hz
SP3 to 40Hz
and SP4 to 50Hz

With 24 volts on LI1 motor speed is 10Hz

With 24 volts on LI1 and LI3 motor speed is 30Hz

With 24 volts on LI1 and LI4 motor speed is 40Hz

With 24 volts on LI1, LI3 and LI4 the motor speed is 50hz

In reverse direction LI1 is replaced by LI2

The second option is to short out +5 to AI1 so the drive starts at maximum speed then by introducing the different logic inputs the preset speeds are called for. The only difference in the programming is that

LSP is set to 0Hz

and SP4 set to 10Hz

With 24 volts on LI1 motor speed is 50Hz

With 24 volts on LI1 and LI3 motor speed is 30Hz

With 24 volts on LI1 and LI4 motor speed is 40Hz

With 24 volts on LI1, LI3 and LI4 the motor speed is 10hz

In reverse direction LI1 is replaced by LI2

One problem with this option is if you lose the preset speed signals the drive will revert to full speed.

Saturday, 21 April 2018

Masalah TV LG padam sendiri

Hari ini saya kongsikan satu lagi pengalaman baru yang semua pemilik TV perlu tahu.

TV yang saya maksudkan berjenama LG, 29 inci.

Masalah TV tersebut ialah ia akan padam sendiri setelah beberapa ketika dihidupkan dan dalam keadaan mode 'standby'. Ianya boleh dihidupkan semula dengan remote control dan akan kembali ke mode 'standby' semula setelah seberapa ketika.

Jika anda mengalami masalah sedemikian, ianya bukan kerosakan pada TV tersebut tetapi hanyalah mengalami masalah setting dan anda boleh memperbetulkannya sendiri seperti pada gambar di bawah:-

1. tekan butang 'mode' pada remote control
2. kemudian pilih 'time'
3. dan pilih 'auto sleep'
4. tukarkan 'auto sleep' dari 'on' ke 'off'

Itu sahaja, selamat mencuba...
Ubah 'auto sleep' dari 'on' ke 'off'

lepas tukar ke 'off' tekan butang 'mode' dan kembali ke skrin asal..

Friday, 13 April 2018

How to reset Telemecanique Altivar 11 (ATV11HU29M2A) back to factory defaults

 
1. Turn on the soft starter

2. go to FUN menu + enter
3. look for FCS + enter
4. Change NO to Inl and
5. press enter key and hold for about 2 seconds.

Sunday, 8 April 2018

Baiki kamera litar tertutup CNB

Ini pengalaman pertama saya membaiki kamera litar tertutup (CCTV) berjenama CNB.

Masalah kamera cctv ini ketika dirujuk kepada saya ialah tiada imej dihasilkan oleh kamera cctv tersebut.
Kamera litar tertutup berjenama CNB
Seperti biasa, jika kita ingin membaiki sesuatu kita haruslah membukanya terlebih dahulu dan gambar berikut merupakan pandangan dalam kamera cctv.
Pandangan dalam setelah penutup dibuka
Setelah diperiksa secara menyeluruh, hanya sebiji kapasitor sahaja yang menyebabkan kamera cctv tersebut tidak berfungsi seperti ditanda dengan anak panah seperti pada gambar di bawah.
Salah satu papan litar yang bermasalah
Kapasitor 470uF/16v tersebut setelah diuji dengan meter hanya mempunyai bacaan 304uF saja.
kapasitor 470uF dengan bacaan 304uF sahaja

Gantikan kapasitor yang rosak
Setelah kapasitor tersebut diganti, kini kamera tersebut kembali berfungsi seperti biasa.

Selamat mencuba...

Baiki power supply 110VAC - SIGMA

Hari ini saya kongsikan pengalaman membaiki transformer/power supply dengan menggunakan bekalan elektrik 110VAC. Kegunaan power supply ini ialah pada lift berjenama SIGMA. Ianya membekalkan 5VDC & 15VDC.

Masalah power supply ini ketika dirujuk kepada saya ialah lampu led berkelip-kelip dan bekalan elektrik tidak berterusan. Bekalan 5V & 15V hanya terjana ketika lampu led menyala dan lampu led hanya menyala kira-kira sekali dalam 2 saat.
Power Supply menggunakan 110VAC
Ketika dibuka, tiada tanda-tanda kerosakan yang boleh dilihat dengan mata kasar. Fius juga berada dalam keadaan baik & cuma bekalan output tidak berterusan.
Setelah dibuka penutup bahagian atas
Setelah diperiksa secara menyeluruh, hanya sebiji kapasitor 47uF/50v yang ditandakan dengan anak panah pada gambar di atas yang mempunyai nilai yang berkurangan melebihi 10%. Ketika diukur dengan meter, bacaan menunjukkan 41.6uF sahaja seperti pada gambar di bawah.
kapasitor 50v 47uF harus ditukar
Setelah diganti & diuji, lampu led pada power supply tersebut tidak lagi berkeli-kelip & setelah diukur dengan meter, bacaan 5VDC & 15VDC berterusan dan tidak terputus-putus seperti ketika baru dirujuk kepada saya.
5.03VDC

15VDC
Untuk makluman, power supply moden iaitu 'switching mode power supply' seperti di atas amat lah sensitif jika kapasitor mengalami masalah dan majoriti boleh dibaiki dengan menggantikan kapasitor sahaja.

Selamat mencuba...